About

Best Practices

...

StorageStorage

When storing batteries, make sure the LEDs display 3-4 green lights, which corresponds to around 50-97 percent charge. Check the batteries every three months of storage to make sure they retain 3-4 LEDs. If not, charge the battery back up to 3-4 LEDs as needed.

Discharge is achieved by plugging a battery into a PHX with a payload installed. Do not run the PHX for more than 1 hour continuously on ground. Batteries slowly discharge over time.

Note

If a charge falls to zero LEDs, the battery may become permanently damaged and no longer recharge.

For longest lifespan, store battery with ambient temperature between 40 F (5 C) and 90 F (32 C). Store batteries in a dry location indoors, out of direct sunlight.

...

Expected Lifespan

PHX battery expected lifespan is 200-500 charge cycles, depending on use. Poor charging and storage habits lead to increased risk of battery damage and shortened lifespan.

...

Damage and Disposal of Battery

Some minor battery swelling may not be a problem, but significant battery swelling may indicate serious internal damage to the battery cells. Maximum allowable swelling of the PHX battery is a total thickness of 2.25 inches as measured at the thickest point of swelling.

Note

Any battery with punctures, deep cuts, strong chemical odor, swelling over 2.25 inches, or leaking cells should not be used or charged.

Dispose of damaged or unusable batteries at a local battery recycling center, in accordance with local regulations.

Panel
panelIconIdatlassian-warning
panelIcon:warning:
bgColor#FFFAE6

Damaged batteries may pose a fire hazard.