Airspeed Calibration



How to Calibrate

Begin Calibration

Press the calibrate button

Block From Wind

Cover the Pitot tube from the wind

Pressurize

Pressurize the Pitot tube

Complete


Troubleshooting

Symptom

Solution(s)

Symptom

Solution(s)

Unable to pressurize

  • Check pitot tip for clogs, debris, or moisture. Replace the tip if needed.

  • Check tube for clogs, debris, or moisture. Replace if needed.

  • Retry the calibration and verify the Pitot is not pressurized or has wind blowing into it during step 1 of the calibration.

Calibration Failed

  • Verify the wing is fully connected to the aircraft.

  • Verify the wing and fuselage connectors are undamaged.

  • Reboot the aircraft and try again. The wings must be connected to the aircraft before the aircraft is powered.